Quality Control & COA Verification
Take a 100% transparent look inside our automated Fmoc solid-phase synthesis line, HPLC/MS analytical release testing lab, aseptic cleanroom packaging, and cold-chain dispatch center.
Visualized Process
Scientific freeze-dried powder production workflow.
Solid-phase Synthesis
Fmoc chain assembly & cleavage
Fmoc synthesis → TFA cleavage → Crude washing → Analytical HPLC check.
Retatrutide-20mg
Batch-verified analytical certificateWhat we test, and what the numbers mean
A batch is released on data, not on a promise. Below is the workflow, the limits we hold, and the honest limits of each measurement.
Process control before the fill
- Vials are washed three times, dried at 120 °C, then depyrogenated at 250 °C.
- Stoppers are alcohol-washed and dried at 110 °C.
- The bulk solution is filtered at 0.22 µm immediately before filling.
- The filling area is ozonated for two hours before each session.
- Each batch is filled, lyophilised, sampled and released only once the sample result is in.
These steps cut bioburden; they do not turn a non-sterile fill into a sterile one. Residual aerobic organisms remain possible, which is why microbial limits are a test you request rather than a claim we make.
Assay and purity
Purity is the main peak’s share of the HPLC chromatogram, and our release target is ≥99%. A few molecules physically cannot reach it — FOX4-DRI, IGF-LR3 and CJC-DAC are the usual examples. If your compound is one of them we quote the achievable figure before you pay, and that figure becomes the specification. Content is measured against a certified reference and reported per vial.
Endotoxin
Sourced to ≤10 EU/mg on the supplier’s COA; measured values typically sit below 0.5 EU/mg. Tighter limits are quoted case by case.
Heavy metals and microbial limits
Both are tested on request. State the requirement when you order — once a batch is packed there is no sample result to compare against, and no claim can be raised later.
Which reports we accept
Only FREEDOM or JANO reports count as claim evidence. If their result disagrees with our release data we re-test at our cost, and the new report is issued in PEPMAKE’s name. Where the re-test passes, that report governs.
How to read a content figure
Almost every laboratory reports content by external standard: run a reference of known content alongside your sample, compare peak areas, and scale. Content = reference content × (sample area ÷ reference area).
Three things move that number — whether the reference is properly characterised, how much powder was actually weighed (sparingly soluble material is easy to under-weigh), and injection consistency. Most labs publish none of them.
There is an absolute route: every amino acid carries at least one nitrogen atom, so nitrogen analysis converts straight to peptide mass. It works, but a nitrogen-rich impurity inflates the result.
In practice ±5% is normal and ±10% is still respectable. Do not fight over a few percent on a 99% target. And keep purity and content apart: purity is the share of the main peak, content is how much peptide is in the vial. A 99% pure powder can still assay at 90% because the rest is water, acetate and counter-ions.
Reconstitution and clarity
Every product we ship reconstitutes; test it before dispatch if you want proof. AOD9604 5 mg and 10 mg form a gel roughly two hours after dissolving in 3 ml of water — that is the molecule, not the batch. Everything else stays clear in solution for at least a month in our hands. If your protocol needs a defined clarity window, tell us at order and we test before the box leaves.